This is an old revision of the document!


Portable Dust Extractor - Yorklean WV100

No-Induction Required

This equipment requires no induction prior to use.

PPE Requirements

The extractor can be noisy so consider wearing hearing protection during use. If there is a lot of dust in the woodshop, respiratory protection is also recommended.

Product page: Yorklean WV100

The WV100 features the well proven dual filtration system (0.5 micron filtration) along with a noise reducing acoustic hood. It’s the ideal extractor for small bench mounted machines such as disc sanders and for power tools. It is compact enough to be stored under a bench.

Motor Single phase 1x1200W vacuum motor Speed 12500rpm Supply 230V 50Hz on a 13A 3-pin BS approved moulded plug Collection Capacity 35ltr (approx) Airflow Rate 70 l/sec (+/-5%) Filters 2 stage, up to 0.5 micron Suction 2500mm WG (+/-5%) Inlet Size (Internal Diameter) 58mm Size 370mm diam x 510mm height Approx. Weight 10kg Noise Level 75dB(A)

Product Overview:

Full Instruction Manual:

Trend T33A User Manual.pdf

Check if the bag needs emptying or changing before and after use.
Airborne wood dust is hazardous to health. Wood dust should always be vacuumed rather than swept with a brush to avoid creating airborne dust.
Large chips, eg from planing or the wood lathe should be gathered up using the dustpan and brush and binned before vacuuming.
Do not use without a bag fitted.
Do not use without a filter fitted.
No Wet Use.

This machine is for use with wood dust in the wood workshop, if it is used with liquids it will get gummed up inside.

Do not use this extractor for liquids … unless it is an emergency. Instead, use the Charles vacuum from the CNC for liquids.

If there is an emergency need to use this for liquids, it has that capability, please read page 10 of the manual for how to set it up. (clean out wood dust, remove bag, change filter) and ensure that you clean and dry the vacuum after use.

Extraction velocity monitor & filter shaker button

If the extraction velocity monitor is red, press and hold the filter shaker button for 3 seconds. (device/extraction must be on) the filter will continue the shaker function for a further 5 seconds after release.

Removing the Collection Bag

The collection bag must be replaced when the extraction velocity monitor goes to red and stays on red.

  1. Unlock the container catches and remove the lid.
  2. To remove bag undo the container hose pull bag off the container deflector flange.
  3. Close the bag by flipping the tab over (fig 4 below).
  4. Dispose of the filter in a suitable container according to the applicable laws.
  5. It is good practice to change the bag regularly to guarantee optimal cooling of the motor.

Inserting a new Collection Bag

  1. Spare collection bags are kept in the cupboard in the hall. If we are running low, please ask on the consumables forum thread for more to be ordered.
  2. The collection bag has a card-reinforced opening with a tab at the top.
  3. Handle the bag with care to avoid damage.
  4. Insert the collection bag into the container with the opening towards the front of the vacuum cleaner (images below).
  5. Pull the bag opening over the container deflector flange ensuring the collection bag opening passes over the ridge on the container deflector.
  6. Fold out the rest of the bag downwards into the container.

Power Take off

Auto-Start 1500W Power Tool Take-Off automatically turns the extractor on and off with the connected power tool.

Changing the Hepa Filter